Installation Instructions and Homeowner’s Manual20007890 5/08 Rev. 8DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICIN
10TDVDSN Series Direct Vent Gas Fireplace20007890VVVVVVVXXXDEBBBCBMBAJKFLVENT TERMINATION AIR SUPPLY INLETAREA WHERE TERMINAL IS NOT PERMITTEDHI
11TDVDSN Series Direct Vent Gas Fireplace20007890Fig. 7a Termination clearances.General Information on Assembling Vent PipesCanadian Installations:Th
12TDVDSN Series Direct Vent Gas Fireplace20007890Since it is very important that the vent-ing system maintain its balance between the combustion air i
13TDVDSN Series Direct Vent Gas Fireplace20007890FP1012Top vent max run1/25/00 djt20' (6m)7.5' (2.3m)Pipe Straps Every 3’ (914mm)Firestop/
14TDVDSN Series Direct Vent Gas Fireplace20007890STEP 6Use appropriate length of pipe sections - telescopic or fixed - and install the horizontal vent
15TDVDSN Series Direct Vent Gas Fireplace20007890FP1242Fig. 19 Through the wall.STEP 7Apply high temperature sealant to 4” (102 mm) and 7” (179 mm) c
16TDVDSN Series Direct Vent Gas Fireplace20007890Below Grade InstallationsWhen it is not possible to meet the required vent ter-minal clearances of 12
17TDVDSN Series Direct Vent Gas Fireplace200078901234Max. 8' (2.4m)FP1245through the roof90 & 45 degree 12/021 + 2 + 3 + 4 = 270°FP1245Fig.
18TDVDSN Series Direct Vent Gas Fireplace20007890When installing the 33TDVDSN with a Vertical Through-the-Roof configured flue system the restrictor pla
19TDVDSN Series Direct Vent Gas Fireplace20007890If there is a room above ceiling level, firestop spacer must be installed on both the bottom and the t
2TDVDSN Series Direct Vent Gas Fireplace20007890Installation & Operating Instructions General Information, Warnings, Cautions ...
20TDVDSN Series Direct Vent Gas Fireplace20007890Twist Lock Venting Components584Aventing componentsrear vent term4/6/99 djt584BVent componentsSt
21TDVDSN Series Direct Vent Gas Fireplace20007890Only glass approved by CFM Corporation should be used on this fireplace. The top louvre panel is remov
22TDVDSN Series Direct Vent Gas Fireplace20007890Unpack the logs from packaging and remove each log from its wrapping materials.The logs are fragile a
23TDVDSN Series Direct Vent Gas Fireplace20007890Burneror 120 Volt ThermostatWire to Unit By Others(by Others)ON/OFF Wall SwitchBLACKJunction Box120 V
24TDVDSN Series Direct Vent Gas Fireplace200078901. STOP! Read the safety information above.2. Set the thermostat, if used, to the lowest set-ting.
25TDVDSN Series Direct Vent Gas Fireplace20007890TroubleshootingNOTE: Before troubleshooting the gas control system, be sure external shut off is in
26TDVDSN Series Direct Vent Gas Fireplace20007890 NOTE: Failure to adjust air shutter to proper setting will produce sooting.8. Fasten pilot to burn
27TDVDSN Series Direct Vent Gas Fireplace20007890 Kit Number Conversion Parts Included with Kit 20007864 20007891 20007903 Main Burner Ori
28TDVDSN Series Direct Vent Gas Fireplace20007890Unit AdjustmentOnce installed, the unit should be operated at least three (3) times to ensure that al
29TDVDSN Series Direct Vent Gas Fireplace20007890Motor and Blower for Fan Kit (optional)This motor has been factory oiled and under normal operating c
3TDVDSN Series Direct Vent Gas Fireplace20007890This gas fireplace should be installed by a qualified installer, preferably NFI or WETT (Canada) certifie
30TDVDSN Series Direct Vent Gas Fireplace20007890IMPORTANT: Always check for gas leaks with a soap and water solution. Do not use open flame for leak t
31TDVDSN Series Direct Vent Gas Fireplace200078902023121311d1c1b1a2349197890TDVDSN parts7/0418 212236/39TDVN Logs251b1a33TDVN Logs11d1c24123410CFM
32TDVDSN Series Direct Vent Gas Fireplace20007890 7. DS Ignition Control (Synetek DS2070S) 20007288 20007288 20007288 8. Spark Electrode w/Wir
33TDVDSN Series Direct Vent Gas Fireplace20007890FK24 Fan AssemblyThis auxiliary fan system increases the efficiency of the circulation of the heating
34TDVDSN Series Direct Vent Gas Fireplace20007890Bay window kits are available for the 33TDVDSN/P/33RDVDSN/P, 36TDVDSN/P/36RDVDSN/P & 39TDVDSN/P/3
35TDVDSN Series Direct Vent Gas Fireplace20007890Remote ControlsBay Window ScreenBay Window Screen Kits are available for the 33TDVDSN, 36TDVDSN &
36TDVDSN Series Direct Vent Gas Fireplace20007890One Year Limited WarrantyTEMCO Fireplace Products Vented Gas FireplacesThis warranty is limited to TE
37TDVDSN Series Direct Vent Gas Fireplace20007890TEMCO FIREPLACE PRODUCTS DIRECT VENT FIREPLACES INSTALLATION AND STARTUP CHECKLISTCustomer CopyNOTE:
38TDVDSN Series Direct Vent Gas Fireplace20007890TEMCO FIREPLACE PRODUCTS DIRECT VENT FIREPLACES INSTALLATION AND STARTUP CHECKLISTInstaller’s CopyNOT
39TDVDSN Series Direct Vent Gas Fireplace20007890Customer CopyModel # ______________________________________I certify that I have followed all codes
4TDVDSN Series Direct Vent Gas Fireplace20007890Installation & Operating InstructionsRequirements for the Commonwealth of MassachusettsAll gas fitt
Efficiency Ratings Model EnerGuide Ratings Fireplace Efficiency (%) 33TDVDSN 57.9 33TDVDSP 57.9 36TDVDSN 58.51 36TDVDSP 58.51 39TDVDSN 65
5TDVDSN Series Direct Vent Gas Fireplace20007890Fireplace DimensionsFig. 1 Fireplace specifications and framing dimensions. Ref. 33TDVDSN 36TDVDSN
6TDVDSN Series Direct Vent Gas Fireplace20007890Locating Your FireplaceA - Flat on wall B - Cross corner C - **IslandD - Room divider E - Flat on
7TDVDSN Series Direct Vent Gas Fireplace20007890A hearth is not mandatory but is recommended for aesthetic purposes. We recommend a noncombustible h
8TDVDSN Series Direct Vent Gas Fireplace20007890The fireplace, when installed, must be elec-trically connected and grounded in accord-ance with local c
9TDVDSN Series Direct Vent Gas Fireplace20007890Your fireplace is approved to be vented either through the side wall, or vertical through the roof.• O